| Management number | 236913956 | Release Date | 2026/07/10 | List Price | US$18.32 | Model Number | 236913956 | ||
|---|---|---|---|---|---|---|---|---|---|
| Category | |||||||||
AmmetersAttention:1.Include a current 2.Please try not to install the meter and current around the high temperature, strong magnetic fieldand large , otherwise the accuracy will be affected.3.In order to obtain a higher precision measurement, it is recommended to "preheat for 5 minutes" beforeadjusting the calibration.4.Sincethe 24V battery charge full of floating voltage may be over 30V, so "no" recommended direct use it.5.When you select range, not the larger the better. the larger the range, the larger the error, it is recommendedthat it is 1.5 or 2 times as large as the actual test value.6.This meter and CT have been calibrated by the "one to one". Please don't mix it up when you use it in the laterperiod. If mixed, you need to recalibrate it.Technical Parameters: Supply voltage:DC4-30V(Note:The maximum input voltage can not exceed 30V, or be burnt.)<;30mATest current:DC5A/10A/20A/50A/100ADisplay type:0.52'' LED(red/green)Measurement rate: 500mS / timeMeasurement accuracy:1% (± 2 digits)CT wire length:150mmTerminal wire length:150mmDimension:54*30*21mmMounting hole:47.2*27.3mmFeatures: 1.The wide power supply range, with reverse polarity protection. 2. Use the SMT technology,so consistency is very good. 3. With a current calibration potentiometer, you can calibrate by yourself. T he tolarance is absolutely exit. 4 . CT adopts the design of perforation type wire through the hole,without having to cut wires, without damage, without changing the electric current wire can be achieved current measurements. 5. Since CT and measured wire is isolated completely, this meter can be measured the current of the power positive, negative and any devices, don't need to worry about the ammeter "common ground". 6. The positive and negative current can be measured, and the "positive" current is shown in the positive direction(the decimal point is always bright or not bright), and the "negative" current is shown in the reverse direction(the decimal point flashes slowly. 7. The pressure tolerance between the measured wires is as high as: 2KV. 8. High reliability, high resistance to current shock, no current impact damage ammeter. 9.With two wires,connection is convenient,easy connect to solar system/car/electric vehicle/motorcycle interior wires.It is used to monitor the battery voltage and can be also used for other products. Specification: Calibration Method:The relative error between the instrument and the instrument, or after long-term use, due to component aging or environmental temperature changes caused by the error can be calibrated by the following methods, in order to get more accurate measurements, it is recommended to energize and then preheat more than 5 minutes before recalibration. Current calibration: In the condition of without current, use a screwdriver to adjust the "zero(or 0)" potentiometer that behind the transforme until the decimal point of the ammeter flashes fast to the best; always bright or no light shows positive current, slow flashing shows negative current In the condition of the half of actual measured current value , adjust the "amplitude modulation(or A)" potentiometer by the side of the until it is consistent with the standard meter.If the test accuracy is very high, you can repeat the above two steps to get higher accuracy.Working conditions:Operating temperature: -10 ~ +50 Working humidity: 10 ~ 80% (no condensation)Working pressure: 80 ~ 106kPaSun exposure: no direct exposure
| ASIN | B0G4GNWXFB |
|---|---|
| Color | Green |
| Model | FKLSQYDU |
| Brand Name | FKLSQYDU |
| Part Number | FKLSQYDU |
| Manufacturer | FKLSQYDU |
| Item Dimensions | 7.87 x 0.39 x 0.39 inches |
If you notice any omissions or errors in the product information on this page, please use the correction request form below.
Correction Request Form